Upon a successful connection, the Orca maintenance screen is opened.
The screen displays information as follows:
Serial - This field indicates the Platypus serial number. If you have problems with your Platypus, include the serial number in your error report to Oliotalo Oy.
Kernel - This field indicates the Platypus's Linux operating system kernel version. If you have problems with your Platypus, include the kernel version in your error report to Oliotalo Oy.
Build - This field indicates the Platypus software build number, date, and time.
Signals forward, backward, up, down - These fields contain signals from the forklift movement. The signal threshold is 1 V.
Joystick fwd/bwd, left/right - These fields contain signals from the forklift joystick. The resting current and the threshold when the forklift starts to move must be measured and written down because the server needs this information.
For example, the analog joystick can have a 5 V resting voltage and the forklift can move forward as the voltage increases up to 5,3 V. In this case, the server would need the 5 V and 5,3 V values to know when forklift movement starts and stops.
ACC X/Y/Z - These fields contain signals from the acceleration sensor. There are no default values, because the resting values depend on the Platypus installation position. However, ensure that the values do not change when the forklift does not move. If they do, check that that mounting has been made properly.